TECHNICAL DATABASE
Mitsubishi ElectricMUZ-EF25/35/42/50VE(VEH) – LEDs and fault memory
40 search entries, with any different interpretations for the same signal.
Reference models
MUZ-EF25VE · MUZ-EF35VE · MUZ-EF42VE · MUZ-EF50VE · MUZ-EF25VEH · MUZ-EF35VEH
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| LED-1 | Frequency limitation by current | — |
| LED-10 | Outdoor fan | — |
| LED-11 | Closed service valve | — |
| LED-12 | Current detection | — |
| LED-13 | Bus voltage DC | — |
| LED-14 | Other external anomaly | — |
| LED-16 | Four-way valve or pipe temperature | — |
| LED-2 | Overcurrent protection | — |
| LED-3 | Limitation by temperature/pressure | — |
| LED-4 | Limitation by sending temperature | — |
| LED-5 | High pressure protection | — |
| LED-6 | Serial communication | — |
| LED-7 | Temperature too low | — |
| LED-8 | Converter or correction power factor | — |
| LED-9 | Test mode or service | — |
| MEM-1 | Serial communication | — |
| MEM-10 | Temperature too low | — |
| MEM-11 | Current detection | — |
| MEM-14 | Four-way valve or pipe temperature | — |
| MEM-2 | Outdoor-unit power system | — |
| MEM-3 | External heaters | — |
| MEM-4 | Overcurrent protection | — |
| MEM-5 | High discharge temperature | — |
| MEM-6 | High pressure protection | — |
| MEM-7 | Heat sink or board overheating | — |
| MEM-8 | Outdoor fan | — |
| MEM-9 | Memory or outdoor-unit control | — |
| MEM-EST-1 | Probe debriefing | — |
| MEM-EST-11 | Overcurrent protection | — |
| MEM-EST-12 | Synchronism or compressor start | — |
| MEM-EST-14 | Closed service valve | — |
| MEM-EST-16 | Four-way valve or pipe temperature | — |
| MEM-EST-2 | External air supply | — |
| MEM-EST-3 | Heat sink temperature sensor | — |
| MEM-EST-4 | Supplies temperature board | — |
| MEM-EST-5 | Memory or outdoor-unit control | — |
| MEM-EST-6 | Power module | — |
| MEM-EST-7 | Heat sink or board overheating | — |
| MEM-EST-8 | Bus voltage DC | — |
| MEM-EST-9 | Current detection | — |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.