Home / Mitsubishi Electric / MUZ-EF25/35/42/50VE(VEH) – LEDs and fault memory
DIAGNOSTIC ENTRY · Mitsubishi ElectricLED-1Outdoor-unit power system
MUZ-EF25/35/42/50VE(VEH) – LEDs and fault memory
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MUZ-EF25VE · MUZ-EF35VE · MUZ-EF42VE · MUZ-EF50VE · MUZ-EF25VEH · MUZ-EF35VEH
The same report has 4 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
Outdoor-unit power system
Reading conditions: Outdoor unit
Indicator light pattern · search label, not an alphanumeric display code
LED External Board:1 lampeggi with pause 2,5 seconds
What it means
Outdoor unit. The compressor does not regularly complete the start or repeatedly intervene the power protections.
Possible causes to distinguish
- Compressor or inverter
- Compressor cabling
- Valves and operating conditions
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Examine load, connections and inverter circuit following the diagnostic sequence of the manual.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 33.
External heaters
Reading conditions: Outdoor unit
Indicator light pattern · search label, not an alphanumeric display code
LED External Board:1 lampeggi with pause 2,5 seconds
What it means
Outdoor unit. An outdoor unit probe is open or short.
Possible causes to distinguish
- Thermal or wiring
- Measuring input on the board
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Acquire the detail of the LED external or memory to identify the probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 33.
Memory or outdoor-unit control
Reading conditions: Outdoor unit
Indicator light pattern · search label, not an alphanumeric display code
LED External Board:1 lampeggi with pause 2,5 seconds
What it means
Outdoor unit. The non-volatile memory of external electronics is not read correctly.
Possible causes to distinguish
- Memory or external control circuit
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check the specific diagnosis of the board without confusing it with a communication error.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 33.
Frequency limitation by current
Reading conditions: Unit running
Indicator light pattern · search label, not an alphanumeric display code
LED External Board:1 lampeggi with pause 2,5 seconds
What it means
Unit in operation. The compressor continues to operate at a reduced frequency to limit current draw. This is a protective control function and does not, by itself, prove that a fault has occurred.
Possible causes to distinguish
- High load
- Thermal or coolant exchange conditions
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check performance, filters and air circulation if the condition persists.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 33.
Contact the repair labThe brand, series and code are already in the message