LED-5High pressure protection

MUZ-EF25/35/42/50VE(VEH) – LEDs and fault memory

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MUZ-EF25VE · MUZ-EF35VE · MUZ-EF42VE · MUZ-EF50VE · MUZ-EF25VEH · MUZ-EF35VEH

The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

High pressure protection

Reading conditions: Repeated stop and restart

Indicator light pattern · search label, not an alphanumeric display code

LED External Board:5 lampeggi with pause 2,5 seconds

What it means

Stop and restart repeated. Temperatures or the pressure plate indicate a high pressure condition.

Possible causes to distinguish

  • Insufficient thermal exchange
  • Ventilation or refrigerant circuit
  • Service Valves

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check exchangers, fans and circuit conditions.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 33.

External air supply

Reading conditions: Protected unit

Indicator light pattern · search label, not an alphanumeric display code

LED External Board:5 lampeggi with pause 2,5 seconds

What it means

Protected unit. The external ambient temperature probe is open or short.

Possible causes to distinguish

  • External air heater
  • Wiring or input board

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Compare reading, room temperature and probe connection.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 33.

Contact the repair labThe brand, series and code are already in the message