ELECTRONICAL Repair lab · MILANO

Haier board repair for air conditioners

To request a diagnosis on a Haier board it is important to distinguish a code on the display from a flash count on the external board. The database deals separately with the Forward VHJ(DB), Advanced ES2VHA and variants 1U ERA/ERB and EAB. Mixing these tables can turn a correct signal into a diagnosis related to the wrong machine.

E7: the connection between internal and external

In the documented Forward and Advanced families, E7 concerns communication between the indoor and outdoor units. The indication requires separate checks of power supplies, connections and communication circuits. Its presence does not prove that both boards are faulty and does not automatically identify which board should be sent to the repair lab.

Photograph the model of the interior and the exterior. Indicates whether the defect appears immediately, after a certain period or after an intervention. If the technician has already recorded the indications of the external board, it also attaches those along with the display code.

Two flashes and F1: read the documented correspondence

Two LED1 flashes are associated with the IPM protection and the F1 code. In the Advanced series, the table shows F1 directly with the corresponding external count. The link between these two indications is usable because it appears in the family documentation.

To evaluate a power board, it is necessary to distinguish the module from the compressor and operating conditions. It shows if the compressor tries to leave and what tests were carried out by qualified personnel. It is not enough to describe the component as “inverter file Haier”.

Units 1U have separate tables per variant

For units 1U ERA/ERB, the source lists flash counts; for EAB there is a dedicated table. High pressure signaling, for example, uses different references: 44 lampeggi in the first group and code 42 in the second.

The request therefore contains the whole acronym, including the final letters. Add the board label and a readable photo of the signal. These data allow the repair lab to identify the electronics to be examined and evaluated the feasibility of a targeted repair.

Models and references of this guide

AW09ES2VHA · AW12ES2VHA · AW18ES2VHA · AW24ES2VHA · 1U09ES2VHA · 1U12ES2VHA · 1U18ES2VHA · 1U24ES2VHA · 1U28HS1ERA · 1U36HS1ERA · 1U48LS1ERA · 1U48LS1ERB · 1U60IS1ERA · 1U60IS1ERB · AU60NAIESA · 1U48LS1EAB · 1U48IS1EAB · 1U60LS1EAB · HSU09VHJ(DB) · HSU12VHJ(DB) · HSU18VHJ(DB) · HSU24VHJ(DB)

Model and code of PCB must be verified before defining repair. The presence in the list does not guarantee compatibility between boards.

View codes in the correct series

The series in the database

Contact the repair labWe start from the model and problem of your machine

MAKE AN INFORMED CHOICE

Your fault is our starting point.

Discuss the fault directly with us. We assess whether repair is possible and provide a quote before starting. Bench tests are selected to suit the board.