Haier1U HS/LS/IS ERA/ERB – outdoor-unit flash patterns
26 search entries, with any different interpretations for the same signal.
The table at pagina18 lists flash counts, not F/E codes of the display.
Reference models
1U28HS1ERA · 1U36HS1ERA · 1U48LS1ERA · 1U48LS1ERB · 1U60IS1ERA · 1U60IS1ERB · AU60NAIESA
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| LED-1 | Memory EEPROM abnormal | 1 lampeggi, LED 1 |
| LED-10 | External defrosting temperature sensor | 10 lampeggi, LED 10 |
| LED-11 | Suction temperature sensor | 11 lampeggi, LED 11 |
| LED-12 | External ambient temperature sensor | 12 lampeggi, LED 12 |
| LED-13 | Discharge temperature sensor | 13 lampeggi, LED 13 |
| LED-15 | Internal and external communication | 15 lampeggi, LED 15 |
| LED-16 | Insufficient Refrigerant or Extruded discharge Line | 16 lampeggi, LED 16 |
| LED-17 | Switching valve four abnormal ways | 17 lampeggi, LED 17 |
| LED-18 | Overcurrent during frequency change | 18 lampeggi, LED 18 |
| LED-19 | Overcurrent protection detected by software | 19 lampeggi, LED 19 |
| LED-2 | Overcurrent during decrease frequency | 2 lampeggi, LED 2 |
| LED-23 | Module too hot or anomaly module sensor | 23 lampeggi, LED 23 |
| LED-24 | Overcurrent compressor detected by software | 24 lampeggi, LED 24 |
| LED-27 | Connection to the absent compressor | 27 lampeggi, LED 27 |
| LED-28 | Overvoltage protection module | 28 lampeggi, LED 28 |
| LED-29 | Protection undervoltage module | 29 lampeggi, LED 29 |
| LED-3 | Constant compressor speed overcurrent | 3 lampeggi, LED 3 |
| LED-38 | Anomalous communication between modules | 38 lampeggi, LED 38 |
| LED-39 | Intermediate temperature sensor capacitor | 39 lampeggi, LED 39 |
| LED-4 | Communication between connection board and module | 4 lampeggi, LED 4 |
| LED-43 | Low pressure pressure dianomy | 43 lampeggi, LED 43 |
| LED-44 | High pressure pressure dianomy | 44 lampeggi, LED 44 |
| LED-5 | Overcurrent compressor | 5 lampeggi, LED 5 |
| LED-7 | Locked compressor or abnormal operation | 7 lampeggi, LED 7 |
| LED-8 | Too high temperature protection | 8 lampeggi, LED 8 |
| LED-9 | Motor blower DC abnormal | 9 lampeggi, LED 9 |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.