E5Communication during operation
KX/KXR/KXZ – VRF and subcodes
Not all subcodes belong to all generations. E30/E64 are specific KXZW; E36-3 KX6; E44 KXZ; E60 KX4/KX6.
Documented models
KX4 · KXR4 · KX6 · KXR6 · KXZ · KXZP · KXZR · KXZX · KXZRX · KXZW
What it means
Communication during operation. The control does not receive the data expected from the specified component; a connection problem must be distinguished from an electronic defect.
Possible causes to distinguish
- Open communication line, incorrect connection or electrical interference.
- One of the units has no power supply, or the communication circuit is faulty.
What to tell the repair lab
Record the full code and photograph the display and the nameplates of the indoor and outdoor units. Tell the laboratory when the shutdown occurs and whether it affects one or more units; avoid repeated restarts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify which section of the communication link the indication refers to.
- Check the power supplies, wiring and address configuration, then the transmitting and receiving circuits.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Heavy Industries Service Support Handbook, revisione 18/06/2024 r9 · page 16 (PDF17).
Contact the repair labThe brand, series and code are already in the message