DIAGNOSTIC ENTRY · Mitsubishi Electric

MEM-14Power module

MXZ-2A30/40/52VA – LEDs and fault memory

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MXZ-2A30VA · MXZ-2A40VA · MXZ-2A52VA

The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

Power module

Reading conditions: Memory mode

Indicator light pattern · search label, not an alphanumeric display code

Spia OPERATION interna:14 flashes in memory recall

What it means

Memory mode. The control signals the power module or a short in the circuit that feeds the compressor.

Possible causes to distinguish

  • Module IPM
  • Compressor winding or short connection

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Exclude compressor and wiring failures before evaluating the board.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 122.

Closed service valve

Reading conditions: Memory mode

Indicator light pattern · search label, not an alphanumeric display code

Spia OPERATION interna:14 flashes in memory recall

What it means

Memory mode. The control detects conditions compatible with a closed valve. Closed valve: only MXZ-2A30VA and MXZ-2A40VA-E2.

Possible causes to distinguish

  • Closed valve or coolant circulation

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check valve status and refrigerator path.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 122.

Contact the repair labThe brand, series and code are already in the message
Look up this code in the search toolAll codes for this seriesMitsubishi Electric electronic board repair