
ELECTRONIC SERVICE MILANO ARCHIVE
CR-C1155DXHN8, 1FA4B1B091200-2
Logic board CR-C1155DXHN8 photographed on the repair lab bench. Its code is visible along the lower edge.
Talk about this board with the repair lab →ELECTRONICAL Repair lab · MILANO
In the Sanyo plants, the complete reference of the machine allows to separate families that can have similar denominations. The database recalls the Mini ECO-i SPW-CR365/605 GXH documentation and maintains its explicit scope. A Sanyo board must be connected to the model and revision actually present, before discussing a possible repair.
E04 means that the indoor unit is not receiving data from the outdoor unit; E06 concerns the outdoor unit receiving signals from the indoor units. These indications help describe the communication problem, but do not, by themselves, identify the faulty circuit.
If the system includes multiple units, it indicates which ones are still and where the alarm is displayed. Add any recent changes to your configuration or links. For the repair lab it is important to distinguish the board of a single internal from a module that participates in the control of the whole plant.
In the reference Mini ECO-i used, P13 concerns the loss of synchronism, while H31 recalls the protection of the power module. These indications require a comparison between drive, detection and compressor conditions.
Report if the compressor attempts to start, if the block is under load and what checks have already been carried out on the system. An external component of the board can affect the operation of the inverter; the electronic evaluation must therefore start from a description of the fault and not from the alarm only.
SPW series are not one diagnostic family. In particular, the Mini ECO-i GXH reference does not automatically demonstrate the correspondence of codes with other series Sanyo or with machines Panasonic, Argo and Airwell.
To request an evaluation prepares indoor and outdoor tags, board nameplate and legible circuit photographs. If there is a manual of the specific machine, please attach the page describing the error. The repair lab can thus identify the component and evaluate the intervention without relying on the simple resemblance to a board found online.
SPW-CR365GXH56 · SPW-CR605GXH56 · SPW-CR365GXH8 · SPW-CR605GXH8
Model and code of PCB must be verified before defining repair. The presence in the list does not guarantee compatibility between boards.
REAL FOTOGRAPHICES OF OUR ARCHIVE
Compare readable abbreviations and send the photo of your electronics. Identification of the PCB and model of the unit are both useful to open a diagnosis request.

ELECTRONIC SERVICE MILANO ARCHIVE
Logic board CR-C1155DXHN8 photographed on the repair lab bench. Its code is visible along the lower edge.
Talk about this board with the repair lab →
ELECTRONIC SERVICE MILANO ARCHIVE
Module HIC-C1155GDXH8: the board code and connector references can be read in the photograph. Compare these identifiers with the installed board.
Talk about this board with the repair lab →
ELECTRONIC SERVICE MILANO ARCHIVE
Board FIL-C906VH8 photographed in the repair lab, with capacitors and inductors visible. The identifier on the board distinguishes it from the logic board.
Talk about this board with the repair lab →Pictures from original page of Electronic Service Milano. Photography identifies the circuit shown; compatibility with a machine must be verified through nameplate and documentation.
SPW-C0705DXHN8 · SPW-C0905DXHN8 · SPW-C1155DXHN8 · SPW-C1305DXHN8 · SPW-C1405DXHN8 · SPW-C0706DXHN8 · SPW-C0906DXHN8 · SPW-C1156DXHN8 · SPW-C1306DXHN8 · SPW-C1406DXHN8 · SPW-C1606DXHN8 · SPW-C1806DXHN8 · SPW-CR1154GDZH8 · AES10MI3H · SPW-CR364GVH8B · SPW-CR484GVH8B · SPW-CR604GVH8B · MFL 80R-3 / 7SP14R012 · MFL 100R-3 / 7SP14R013 · MFL 120R-3 / 7SP14R014 · MFL 140R-3 / 7SP14R029 · MFL 160R-3 / 7SP14R030
The references are those mentioned in the historical page of the repair lab. The correspondence with each photographed board requires verification of model, code and revision.
See the pages of historical modelsMAKE AN INFORMED CHOICE
Discuss the fault directly with us. We assess whether repair is possible and provide a quote before starting. Bench tests are selected to suit the board.
How we assess an electronic board