F18 / F18Heater outlet sensor THO
ESTIA HWS series 3 – A10-006-1
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
HWS-803H-E(TR) · HWS-1103H-E(TR) · HWS-1403H-E(TR) · HWS-1103H8-E · HWS-1103H8R-E · HWS-1403H8-E · HWS-1403H8R-E · HWS-1603H8-E · HWS-1603H8R-E · HWS-803XWHM3-E(TR) · HWS-803XWHT6-E(TR) · HWS-803XWHD6-E · HWS-803XWHT9-E · HWS-1403XWHM3-E(TR) · HWS-1403XWHT6-E(TR) · HWS-1403XWHD6-E · HWS-1403XWHT9-E(TR)
What it means
The sensor at the exit of the heater is open or short.
Possible causes to distinguish
- Open-circuit or short-circuited sensor, intermittent connection, or incorrectly installed sensor.
- Check the board’s input circuit after checking the sensor and wiring.
What to tell the repair lab
Photograph the fault indication and nameplate and tell the laboratory when the shutdown occurs. Do not open electrical compartments or make repeated restart attempts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify the affected sensor and compare its measured value with the characteristic curve in the manual.
- Check the connector and wiring before concluding that the board is faulty.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Toshiba ESTIA – Service Manual A10-006-1, revisione marzo2012 · page 86 (PDF87).