A12 / A12Insufficient heating or sanitary water support
ESTIA HWS series 3 – A10-006-1
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
HWS-803H-E(TR) · HWS-1103H-E(TR) · HWS-1403H-E(TR) · HWS-1103H8-E · HWS-1103H8R-E · HWS-1403H8-E · HWS-1403H8R-E · HWS-1603H8-E · HWS-1603H8R-E · HWS-803XWHM3-E(TR) · HWS-803XWHT6-E(TR) · HWS-803XWHD6-E · HWS-803XWHT9-E · HWS-1403XWHM3-E(TR) · HWS-1403XWHT6-E(TR) · HWS-1403XWHD6-E · HWS-1403XWHT9-E(TR)
What it means
After the intervention of the support heater the thermal conditions are not met; check the load and supply/command of the heaters.
Possible causes to distinguish
- Thermal/water conditions outside the conditions provided.
- Probe, thermal exchange and control circuit to be checked.
What to tell the repair lab
Photograph the fault indication and nameplate and tell the laboratory when the shutdown occurs. Do not open electrical compartments or make repeated restart attempts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare real temperature and read value from the control unit.
- Check flow rates, circuit conditions and sensors before electronic evaluation.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Toshiba ESTIA – Service Manual A10-006-1, revisione marzo2012 · page 85 (PDF86).
Contact the repair labThe brand, series and code are already in the message