Home / Mitsubishi Electric / MXZ-3A54/4A71/4A80/5A100VA – LEDs and fault memory
DIAGNOSTIC ENTRY · Mitsubishi ElectricLED1-ON-LED2-5External air supply
MXZ-3A54/4A71/4A80/5A100VA – LEDs and fault memory
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-3A54VA · MXZ-4A71VA · MXZ-4A80VA · MXZ-5A100VA
The same report has 3 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
External air supply
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 5 lampeggi
What it means
Table LED in operation: fixed units or repeated stops. The external ambient temperature probe is open or short.
Possible causes to distinguish
- External air heater
- Wiring or input board
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare reading, room temperature and probe connection.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
External exchange probe
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 5 lampeggi
What it means
Table LED in operation: fixed units or repeated stops. The external heat exchanger is open or short.
Possible causes to distinguish
- Exchanger probe
- Connector or board input
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check the exchanger's specific probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
Probe debriefing
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 5 lampeggi
What it means
Table LED in operation: fixed units or repeated stops. The probe used for defrosting is signaled open or short.
Possible causes to distinguish
- Debrining thermostat
- Connection or input board
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check the probe and its connection; the machine can continue in protection under the conditions indicated by the manual.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
Contact the repair labThe brand, series and code are already in the message