E6Discharge temperature sensor
MXZ18/32RV – outdoor-unit display
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-18RV · MXZ-32RV
Reading conditions: Outdoor unit seven-segment display
What it means
The termistore of the pipe is signaled open or short.
Possible causes to distinguish
- Probe sent
- Wiring or connector
- Acquisition circuit
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare resistance and temperature of the output probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB227B – MSC07/09/12RV e MXZ18/32RV · page 126.
Contact the repair labThe brand, series and code are already in the message