Mitsubishi ElectricMXZ-A26/32WV – pair of outdoor-unit LEDs
24 search entries, with any different interpretations for the same signal.
Reference models
MXZ-A26WV · MXZ-A32WV
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| LED1-1-LED2-ON | Frequency limitation by current | — |
| LED1-13-LED2-OFF | Outdoor fan | — |
| LED1-2-LED2-OFF | Overcurrent protection | — |
| LED1-2-LED2-ON | Limitation by temperature/pressure | — |
| LED1-3-LED2-OFF | High discharge temperature | — |
| LED1-3-LED2-ON | Limitation by sending temperature | — |
| LED1-4-LED2-OFF | Heat sink or board overheating | — |
| LED1-4-LED2-ON | Temperature too low | — |
| LED1-5-LED2-OFF | High pressure protection | — |
| LED1-5-LED2-ON | Limitation by temperature/pressure | — |
| LED1-8-LED2-OFF | Converter or correction power factor | — |
| LED1-9-LED2-OFF | Bus voltage DC | — |
| LED1-9-LED2-ON | Test mode or service | — |
| LED1-ON-LED2-1 | Indoor unit and expansion valve | — |
| LED1-ON-LED2-10 | Supplies gas tube circuit A | — |
| LED1-ON-LED2-11 | Communication between external boards | — |
| LED1-ON-LED2-12 | Pass detection for zero | — |
| LED1-ON-LED2-2 | Outdoor-unit power system | — |
| LED1-ON-LED2-3 | Discharge temperature sensor | — |
| LED1-ON-LED2-4 | Heat sink temperature sensor | — |
| LED1-ON-LED2-5 | Probe debriefing | — |
| LED1-ON-LED2-6 | Current detection | — |
| LED1-ON-LED2-7 | Memory or outdoor-unit control | — |
| LED1-ON-LED2-ON | Normal Indication | — |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.