Home / Mitsubishi Electric / MXZ-A14/18WV – pair of outdoor-unit LEDs
DIAGNOSTIC ENTRY · Mitsubishi ElectricLED1-ON-LED2-5Probe evaporation temperature
MXZ-A14/18WV – pair of outdoor-unit LEDs
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-A14WV · MXZ-A18WV
The same report has 3 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
Probe evaporation temperature
Reading conditions: Unit stopped or repeated shutdowns
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 5 lampeggi
What it means
Fixed units or repeated shutdowns. The control detects an open circuit or a short circuit in the evaporation probe.
Possible causes to distinguish
- Evaporation probe
- Connections or input board
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check probe and connector according to the variant.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 53.
High pressure protection probe
Reading conditions: Unit stopped or repeated shutdowns
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 5 lampeggi
What it means
Fixed units or repeated shutdowns. The termistore indicated by the manual as a high pressure protection probe is open or short.
Possible causes to distinguish
- Exchanger probe
- Connector or board input
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check the high pressure protection probe and the CN662 connector.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 53.
Probe debriefing
Reading conditions: Unit running
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 5 lampeggi
What it means
Unit in operation. The probe used for defrosting is signaled open or short.
Possible causes to distinguish
- Debrining thermostat
- Connection or input board
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check the probe and its connection; the machine can continue in protection under the conditions indicated by the manual.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 54.
Contact the repair labThe brand, series and code are already in the message