DIAGNOSTIC ENTRY · Mitsubishi Electric

LED1-ON-LED2-5Probe evaporation temperature

MXZ-A14/18WV – pair of outdoor-unit LEDs

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MXZ-A14WV · MXZ-A18WV

The same report has 3 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

Probe evaporation temperature

Reading conditions: Unit stopped or repeated shutdowns

Indicator light pattern · search label, not an alphanumeric display code

LED1 steady red; LED2 yellow 5 lampeggi

What it means

Fixed units or repeated shutdowns. The control detects an open circuit or a short circuit in the evaporation probe.

Possible causes to distinguish

  • Evaporation probe
  • Connections or input board

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check probe and connector according to the variant.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 53.

High pressure protection probe

Reading conditions: Unit stopped or repeated shutdowns

Indicator light pattern · search label, not an alphanumeric display code

LED1 steady red; LED2 yellow 5 lampeggi

What it means

Fixed units or repeated shutdowns. The termistore indicated by the manual as a high pressure protection probe is open or short.

Possible causes to distinguish

  • Exchanger probe
  • Connector or board input

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check the high pressure protection probe and the CN662 connector.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 53.

Probe debriefing

Reading conditions: Unit running

Indicator light pattern · search label, not an alphanumeric display code

LED1 steady red; LED2 yellow 5 lampeggi

What it means

Unit in operation. The probe used for defrosting is signaled open or short.

Possible causes to distinguish

  • Debrining thermostat
  • Connection or input board

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check the probe and its connection; the machine can continue in protection under the conditions indicated by the manual.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 54.