DIAGNOSTIC ENTRY · Mitsubishi Electric

MEM-11Bus voltage DC

MUZ-HC25/35VA(VAB) – LEDs and fault memory

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MUZ-HC25VA · MUZ-HC35VA · MUZ-HC35VAB

The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

Bus voltage DC

Reading conditions: Memory mode: do not use table LED in operation

Indicator light pattern · search label, not an alphanumeric display code

Internal OPERATION indicator:11 lampeggi in fault call

What it means

Memory mode: do not use table LED in operation. The continuous voltage of the inverter circuit does not fall into the intended field or is not detected correctly.

Possible causes to distinguish

  • Power supply
  • Power circuit or measuring DC

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Distinguish abnormal power and fault of the conversion/relevance circuit.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 28.

Current detection

Reading conditions: Memory mode: do not use table LED in operation

Indicator light pattern · search label, not an alphanumeric display code

Internal OPERATION indicator:11 lampeggi in fault call

What it means

Memory mode: do not use table LED in operation. The current is not consistently detected by the measuring circuit.

Possible causes to distinguish

  • Sensor or measuring circuit
  • Compressor connections

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Compare the electrical measurement with reading the control.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 28.

Contact the repair labThe brand, series and code are already in the message
Look up this code in the search toolAll codes for this seriesMitsubishi Electric electronic board repair