DIAGNOSTIC ENTRY · Mitsubishi ElectricMEM-11Bus voltage DC
MUZ-HC25/35VA(VAB) – LEDs and fault memory
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MUZ-HC25VA · MUZ-HC35VA · MUZ-HC35VAB
The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
Bus voltage DC
Reading conditions: Memory mode: do not use table LED in operation
Indicator light pattern · search label, not an alphanumeric display code
Internal OPERATION indicator:11 lampeggi in fault call
What it means
Memory mode: do not use table LED in operation. The continuous voltage of the inverter circuit does not fall into the intended field or is not detected correctly.
Possible causes to distinguish
- Power supply
- Power circuit or measuring DC
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Distinguish abnormal power and fault of the conversion/relevance circuit.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 28.
Current detection
Reading conditions: Memory mode: do not use table LED in operation
Indicator light pattern · search label, not an alphanumeric display code
Internal OPERATION indicator:11 lampeggi in fault call
What it means
Memory mode: do not use table LED in operation. The current is not consistently detected by the measuring circuit.
Possible causes to distinguish
- Sensor or measuring circuit
- Compressor connections
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare the electrical measurement with reading the control.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 28.