Home / Mitsubishi Electric / MUZ-HC25/35VA(VAB) – LEDs and fault memory
DIAGNOSTIC ENTRY · Mitsubishi ElectricLED-8Synchronism or compressor start
MUZ-HC25/35VA(VAB) – LEDs and fault memory
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MUZ-HC25VA · MUZ-HC35VA · MUZ-HC35VAB
The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
Synchronism or compressor start
Reading conditions: Repeated stop and restart
Indicator light pattern · search label, not an alphanumeric display code
LED External Board:8 lampeggi with pause 2,5 seconds
What it means
Stop and restart repeated. The waveform or compressor behaviour is not consistent with the expected drive.
Possible causes to distinguish
- Compressor or connections
- Circuit inverter
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check compressor connections and electrical behavior.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 29.
Converter or correction power factor
Reading conditions: Operating unit: PAM protection, not necessarily a fault
Indicator light pattern · search label, not an alphanumeric display code
LED External Board:8 lampeggi with pause 2,5 seconds
What it means
Operating unit: PAM protection, not necessarily a fault. The protection of the power converter applies.
Possible causes to distinguish
- Network voltage
- Circuit converter or PFC
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check power supply and conversion circuit according to the variant.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 29.