Home / Mitsubishi Electric / MUZ-G09/12SV – outdoor-unit LED
DIAGNOSTIC ENTRY · Mitsubishi ElectricLED-5High pressure protection
MUZ-G09/12SV – outdoor-unit LED
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MUZ-G09SV · MUZ-G12SV
The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
High pressure protection
Reading conditions: Repeated stop and restart
Indicator light pattern · search label, not an alphanumeric display code
LED outdoor:5 lampeggi, break 2,5 seconds
What it means
Stop and restart repeated. Temperatures or the pressure plate indicate a high pressure condition.
Possible causes to distinguish
- Insufficient thermal exchange
- Ventilation or refrigerant circuit
- Service Valves
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check exchangers, fans and circuit conditions.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB245B – MSZ/MUZ-G09/12/20SV · page 71.
Probe debriefing
Reading conditions: Unit running
Indicator light pattern · search label, not an alphanumeric display code
LED outdoor:5 lampeggi, break 2,5 seconds
What it means
Unit in operation. The probe used for defrosting is signaled open or short.
Possible causes to distinguish
- Debrining thermostat
- Connection or input board
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check the probe and its connection; the machine can continue in protection under the conditions indicated by the manual.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB245B – MSZ/MUZ-G09/12/20SV · page 71.
Contact the repair labThe brand, series and code are already in the message