TECHNICAL DATABASE
HisenseAS-18UR4STVUH1 – display codes and LEDs
41 search entries, with any different interpretations for the same signal.
Table LED row numbers are not display codes. The codice2 is the temperature compressor sensor; il13 is the temperature protection sent.
Reference models
AS-18UR4STVUH1
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| 0 | No fault detected | — |
| 1 | Outdoor heat exchanger temperature sensor | — |
| 10 | Switching valve four abnormal ways | — |
| 11 | Memory EEPROM anomaly external | — |
| 13 | High temperature protection compressor | — |
| 14 | External air temperature sensor | — |
| 15 | Compressor enclosure temperature control | — |
| 16 | Antifreeze or overload control | — |
| 18 | Missed compressor starter DC | — |
| 19 | Compressor DC out synchronism | — |
| 2 | Compressor temperature sensor | — |
| 3 | Anomalous voltage detection | — |
| 33 | Internal ambient temperature sensor | — |
| 34 | Internal battery temperature sensor | — |
| 36 | Communication between indoor and outdoor units | — |
| 39 | Anomalous internal blower operation | — |
| 4 | Anomalous current transformer | — |
| 40 | Grid protection alarm, column version | — |
| 41 | Passage detection abnormality for zero | — |
| 5 | Power module protection IPM | — |
| 6 | Overvoltage or undervoltage protection | — |
| 7 | Anomalous communication | — |
| 8 | Overload current protection | — |
| 9 | Maximum current control | — |
| LED-000 | No anomaly, LED external off | LED2 0 LED3 0 LED4 0 |
| LED-001 | Internal or related circuit environment sensor | LED2 0 LED3 0 LED4 1 |
| LED-00F | Anomaly indoor/outdoor communication | LED2 0 LED3 0 LED4 F |
| LED-010 | Internal or related circuit exchange sensor | LED2 0 LED3 1 LED4 0 |
| LED-01F | Excess compressor enclosure temperature | LED2 0 LED3 1 LED4 F |
| LED-0F0 | Protection IPM | LED2 0 LED3 F LED4 0 |
| LED-0F1 | Excess compressor temperature | LED2 0 LED3 F LED4 1 |
| LED-0FF | Anomalous indoor fan motor | LED2 0 LED3 F LED4 F |
| LED-100 | Compressor sensor or related circuit | LED2 1 LED3 0 LED4 0 |
| LED-101 | External or related circuit sensor | LED2 1 LED3 0 LED4 1 |
| LED-110 | External or related air sensor | LED2 1 LED3 1 LED4 0 |
| LED-111 | Anomaly external memory | LED2 1 LED3 1 LED4 1 |
| LED-11F | Overvoltage/undervoltage protection | LED2 1 LED3 1 LED4 F |
| LED-1F0 | Overload current protection | LED2 1 LED3 F LED4 0 |
| LED-1F1 | Maximum current control | LED2 1 LED3 F LED4 1 |
| LED-F0F | Compressor DC out synchronism | LED2 F LED3 0 LED4 F |
| LED-FF0 | Compressor DC does not start | LED2 F LED3 F LED4 0 |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.