TECHNICAL DATABASE
DaikinVRV IV and selected series
68 search entries, with any different interpretations for the same signal.
Guidance table retained from the previous release: check the full model and subcode. It does not cover every historical unit.
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| A0 | External protection device switch | — |
| A1 | Anomaly EEPROM / PCB indoor unit | — |
| A3 | Anomaly drainage system | — |
| A6 | Anomaly motor internal fan | — |
| A7 | Anomalous oscillating fin motor | — |
| A9 | Anomaly electronic expansion valve | — |
| AF | Drainage abnormality | — |
| AH | Anomaly filter / automatic cleaning system | — |
| AJ | Anomalous capacity setting | — |
| C1 | Anomaly communication between PCB | — |
| C4 | Anomaly termistore liquid pipe | — |
| C5 | Anomaly termistore gas tube | — |
| C6 | Anomalous combination PCB / fan motor | — |
| C9 | Anomalous air vacuum cleaner | — |
| CE | Anomaly sensor presence / floor | — |
| CJ | Remote control thermal anomaly | — |
| E0 | Anomaly blower or pump exhaust exchanger | — |
| E1 | Anomaly PCB outdoor unit | — |
| E3 | High pressure pressure pressure pressure switch | — |
| E4 | Low pressure abnormality | — |
| E5 | Compressor block | — |
| E7 | Anomaly external fan motor | — |
| E9 | Anomaly electronic expansion valve | — |
| F3 | Anomalous compressor temperature | — |
| F4 | Anomalous intake temperature | — |
| F6 | High pressure in cooling | — |
| H3 | High pressure pressure dianomy | — |
| H4 | Low pressure pressure pressure | — |
| H7 | Anomaly external fan motor | — |
| H9 | Anomalous external air temperature | — |
| HC | Water temperature sensor | — |
| HF | Ice thermal storage alarm | — |
| HJ | Water level thermal accumulation | — |
| J1 | Pressure sensor | — |
| J2 | Current sensor | — |
| J3 | Anomaly termistore mandata tube | — |
| J4 | Gas temperature sensor of the exchanger | — |
| J5 | Anomaly termistore suction tube | — |
| J6 | Anomaly termistore external exchanger | — |
| J7 | Anomaly termistore liquid pipe | — |
| J8 | Anomaly termistore liquid tube exchanger | — |
| J9 | Anomaly termistore gas tube | — |
| JA | Anomalous high pressure sensor | — |
| JC | Low pressure sensor | — |
| L1 | Anomaly PCB inverter | — |
| L4 | Inverter heat dissipator | — |
| L5 | Overcurrent compressor detection | — |
| L8 | Overcurrent compressor | — |
| L9 | Anomaly start compressor | — |
| LC | Communication error PCB inverter/PCB main | — |
| P1 | Squilibrium Voltage Supply | — |
| P3 | Anomaly reactor temperature | — |
| P4 | Anomaly temperature dissipator inverter | — |
| PJ | Anomalous capacity setting / combination PCB | — |
| U0 | Refrigerant deficiency detection | — |
| U1 | Lack of phase / reverse phase second platform | — |
| U2 | Insufficient power supply or instant anomaly | — |
| U3 | Operating test not performed | — |
| U4 | Internal/outdoor unit transmission error | — |
| U5 | Remote command/internal communication error | — |
| U7 | Transmission error between outdoor units | — |
| U8 | Remote Command Communication Error | — |
| U9 | Anomaly of other system units | — |
| UA | incorrect combination | — |
| UC | Central control address duplication | — |
| UE | Central control communication error | — |
| UF | Wiring/configuration anomaly | — |
| UH | System anomaly/redirection | — |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.